M-Bus Converters

Compare CNV150 and CNV250 M-Bus converters: meter capacity, USB/RS232 interfaces, bus planning and the 4G alternative. Request a technical quote.
ATLAS M-Bus Converter

LoRaM-BusM-BusWIRELESSRS-485

Why Choose ATLAS M-Bus Converters?

ATLAS CNV M-Bus converters are designed to connect heat, water and energy meters reliably to central reading systems. Communication compliant with EN 13757-2 and EN 1434-3 supports networks of different sizes. CNV150 and CNV250 have nominal capacities of 150 and 250 meters respectively; actual capacity must be evaluated against meter M-Bus loads and line conditions.

Galvanically isolated USB helps protect the computer side from electrical risks, while RS232 and USB 2.0 provide direct connection flexibility. Short-circuit and overcurrent protection, audible and LED fault warnings and line-noise filtering support reliable operation.

Communication speeds of 300–19,200 baud, non-polarised two-wire connection and optional GSM provide flexibility from building automation to multi-point meter reading projects.

Key benefits

  • CNV150/CNV250 nominal capacities of 150/250 meters.
  • Short-circuit and overcurrent protection.
  • Galvanically isolated USB.
  • Optional GSM communication.
  • LED and audible fault warnings.
  • −20 to +70 °C operating temperature.

Connect M-Bus meters to a local reading system

An M-Bus converter provides communication between compatible heat, water or energy meters and the reading computer. ATLAS product information lists CNV150 and CNV250 options. Selection must consider each meter’s M-Bus load and the cable network alongside the total meter count.

Model comparison

ModelStated maximum capacitySelection check
CNV150150 metersVerify total M-Bus loading, cabling and the polling plan.
CNV250250 metersVerify total M-Bus loading, cabling and the polling plan.

Interfaces and operating features

  • RS232 and USB 2.0 computer interfaces; verify compatibility with the reading software and drivers.
  • M-Bus communication at 300–19200 baud. Meter and converter settings must match.
  • Product information lists short-circuit/overcurrent protection, LEDs and audible alerts.
  • For a two-wire M-Bus network, assess distance together with cable cross-section, capacitance, topology, device loading and data rate.

Local converter or 4G data collector?

For local computer-based meter reading, assess the converter interfaces. ATLAS M-BUS CONVERTER-4G is a separate option for direct MQTT transmission without a computer or external modem. Confirm the GSM hardware and exact CNV150/CNV250 variant during quotation.

Verify meter compatibility

A suitable M-Bus meter interface is required. A standard designation alone does not demonstrate compatibility with every make/model and every data record. Check addressing, reading software and data mapping.

Information needed for model selection

Send meter makes/models, quantity, existing software, the cable layout and your preference for local or cloud reading. These details support capacity and interface selection.

Request a technical converter quote

Other communication solutions

Technical Documents — PDF Downloads

Download the original English documents and their Turkish technical adaptations.

ATLAS M-Bus Converter-4G — Datasheet & Manual

Turkish PDF — Download   English PDF — Download

CNV Series (Wired Converter)
CNV Series (Wired Converter)
Capacity and Models

CNV150: 150 Meter Capacity
CNV250: 250 Meter Capacity

Protection Systems

Short circuit and high current protection (Active output protection)
Galvanically isolated USB Port (Protects the computer against high voltage)

Alert System

LED and Audible Warning System (In case of fault and short circuit)

Connection Interfaces

RS232 and USB 2.0 Support (Direct PC connection without requiring a converter)

Communication Speed

Between 300 baud and 19,200 baud

Power Management

Sleep Mode (Provides energy saving and protects the line when not in use)

GSM Option

Optional internal GSM modem available

Line and Installation Features
Line and Installation Features
Wiring

Non-polarized connection via two wires, regardless of direction

Range

Product information states up to 1500 metres. Verify the usable distance for the project against cable cross-section/capacitance, topology, meter loading and data rate.

Noise Filtering

Filters out external noise on the line

Environmental and Standards
Environmental and Standards
Operating Temperature

Between -20°C and +70°C

Compatibility

Complies with TS EN 1434-3 and TS EN 13757-2 standards

Brand Support

For meters with a suitable M-Bus interface. Verify make/model, data records, addressing and reading-software compatibility before commissioning.

Similar Products

ATLAS USM15 ultrasonik su sayacı – orijinal ürün fotoğrafı

Ultrasonic Water Meters

Mechanical Single-Jet Water Meters

Mechanical Single-Jet Water Meters

Heat / Bill Sharing Systems

Heat / Bill Sharing Systems

Product collage of ATLAS UKM meters and an M-Bus converter

Ultrasonic Heat Meters

Seres Solid mechanical heat meter with temperature sensors

Mechanical Heat Meters

Ball Valve with Sensor Pocket

Ball Valve with Sensor Pocket

Mechanical Multi-Jet Water Meters

Mechanical Multi-Jet Water Meters

Single Jet Water Meters with Pulse Output

Single Jet Water Meters with Pulse Output

Dynamic Balancing / Differential Pressure Balancing Valve

Dynamic Balancing / Differential Pressure Balancing Valve

Pressure Gauges

Pressure Gauges

ESTRON EN 13190 thermometer

Thermometers

Assembly / Disassembly Parts

Assembly / Disassembly Parts

Brass Water Meter Coupling

Brass Water Meter Coupling

ATLAS EH-20

Electromechanical Water Meters

ATLAS termostatik radyatör vanası – oda sıcaklığı kontrolü ve radyatör tesisatı uygulaması

Thermostatic Radiator Valves

Size Nasıl Yardımcı Olabiliriz?