Ultrasonic Heat Meters

ATLAS UKM ultrasonic heat meters measure energy consumption in heating and cooling systems, with M-Bus, pulse and LoRa/LoRaWAN communication options.
Product collage of ATLAS UKM meters and an M-Bus converter
Certified in accordance with MID 2014/32/EU MI004.

LoRaM-BusM-BusWIRELESSRS-485

Why Choose ATLAS UKM Ultrasonic Heat Meters?

ATLAS UKM ultrasonic heat meters are designed for accurate measurement and monitoring of energy consumption in heating and cooling installations. Ultrasonic flow measurement operates without moving mechanical measuring parts. Certification under MID 2014/32/EU MI-004 provides metrological assurance for energy measurement.

M-Bus and other communication options allow integration with central meter reading, building automation and remote monitoring systems. Models suited to different installation requirements help make energy consumption transparent in residential and commercial buildings.

Key benefits

  • MID MI-004 certified measurement.
  • Ultrasonic flow measurement technology.
  • Remote reading and communication options.
  • Integration with building automation systems.
ATLAS USM-65 ultrasonic water meter

UKM series ultrasonic heat meters

ATLAS UKM ultrasonic heat meters measure energy in heating and cooling circuits. Select the body material, installation orientation and connection dimensions for the required model. M-Bus, pulse and LoRa/LoRaWAN communication options must match the ordered hardware and reading infrastructure. Models with the appropriate interface can connect to remote reading systems through ATLAS CNV or a LoRaWAN Gateway.

Ultrasonic heat meter components

UKM series flow rates and connection dimensions

TypeDN (mm)Connection DiameterNominal Flow Rate (qp)[m³/h]Min. Flow Rate (qi)[m³/h]Max. Flow Rate (q)[m³/h]Length (L)[mm]Height (H)[mm]Width (W)[mm]Weight[gr]
UKM15153/4″ Thread1,500,03 / 0,012*3,001109483950
UKM20201″ Thread2,500,055,001309483950
UKM252511/4″ Thread3,500,077,0016010083–
UKM323211/2″ Thread6,000,0612,00180100831100
UKM40402″ Thread10,000,1020,00200120831250
UKM5050Flanged15,000,1530,00200165165–
UKM6565Flanged25,000,2550,00200185185–
UKM8080Flanged40,000,4080,00220200200–
UKM100100Flanged60,000,60120,00250220220–
UKM125125Flanged100,001,00200,00250250250–
UKM150150Flanged150,001,50300,00300285285–
UKM200200Flanged250,002,50500,00350340340–
UKM250250Flanged400,004,00800,00450405405–
UKM300300Flanged560,005,601120,00500460460–

Minimum flow rate and model documentation

This table is for preliminary selection. Confirm minimum flow rates (qi), including the starred 0.012 m³/h value for UKM15, against the current datasheet and type approval documentation of the ordered model. Some minimum flow values differ between the catalogue and web table; do not use them alone as definitive order specifications.

Selecting an ultrasonic heat meter

Pipe size alone is not enough to select a heat meter. Consider the minimum and nominal flow rates, installation length, connection type and communication requirements together.

  • Flow range: Compare each model’s minimum, nominal and maximum flow rates in the table above.
  • Installation: Match the DN, connection size and body length to the system design.
  • Operating conditions: Check temperature, pressure and protection ratings against the selected model’s technical documentation.

What is the difference between UKM15 and UKM20?

The table specifies a nominal flow rate of 1.50 m³/h and an installation length of 110 mm for UKM15, compared with 2.50 m³/h and 130 mm for UKM20. Select the model according to the system’s flow requirements and connection dimensions.

How do mechanical and ultrasonic heat meters compare?

Ultrasonic models measure flow using an ultrasonic principle without moving parts in the flow sensor. Mechanical heat meters use a mechanical flow sensor. Compare each model’s flow range, installation conditions and reading infrastructure.

Remote reading options

Assess M-Bus, pulse and LoRa/LoRaWAN options against your existing automation infrastructure. Explore M-Bus converters and the LoRaWAN Gateway. Confirm communication hardware and compatibility when ordering.

Request a project quotation

Provide the model or DN, design flow rate, installation length, quantity and preferred communication interface.

Request an ultrasonic heat meter quotation

General Structure and Design
General Structure and Design
Product Description

Ultrasonic heat meter used in heating and cooling systems

Principle of Measurement

Ultrasonic flow measurement with no moving parts in the flow sensor. Service life depends on the model, water quality and operating conditions.

Calculation Method

Q = m × c × ∆t (Energy calculation based on flow rate and temperature difference)

Body Material

Brass, Cast Iron

Screen

Detachable from the body, easy-to-read 8-digit LCD display

Assembly

Can be connected horizontally or vertically

Energy Unit

Standard: kWh / Optional: MWh, Gcal, GJ

Measurement Performance
Measurement Performance
Temperature Range

5°C - 90°C

Minimum Temperature Difference (∆t)

0,1°C

Sensor Type

A pair of platinum temperature sensors capable of linear measurement

Magnetic Protection

It is not affected by magnetic fields

Pressure and Strength
Pressure and Strength
Pressure Class

PN16 (Max. Working Pressure: 16 bar, Test Pressure: 16 bar)

Minimum Operating Pressure

2 Bar

Protection Class

The catalogue specifies IP65 for the UKM series. Confirm the protection rating of the ordered model and its components against the technical datasheet and product label.

Communications and Energy
Communications and Energy
Standard Interface

M-Bus and optical interface

Optional Interface

Pulse, RF (Wireless M-Bus), LoRa/LoRaWAN

Compatibility

Compatible with ATLAS CNV or a LoRaWAN Gateway when the selected communication hardware and data format match. Verify interface and software compatibility for the project.

Power Supply

Low-energy-consumption lithium battery

Standards
Standards
Certification

MID 2014/32/EU MI004, TS EN 1434, 2004/22/EC

Accuracy Class

Class 2

Contents of the Pack
Contents of the Pack
Standard

Heat Meter, 2 Klingrit Gaskets, 1 Sensor Fitting and O-ring, Instruction Manual

Note

Union fittings are not included in the delivery.

Similar Products

ATLAS USM15 ultrasonik su sayacı – orijinal ürün fotoğrafı

Ultrasonic Water Meters

Mechanical Single-Jet Water Meters

Mechanical Single-Jet Water Meters

Heat / Bill Sharing Systems

Heat / Bill Sharing Systems

Seres Solid mechanical heat meter with temperature sensors

Mechanical Heat Meters

Ball Valve with Sensor Pocket

Ball Valve with Sensor Pocket

Mechanical Multi-Jet Water Meters

Mechanical Multi-Jet Water Meters

Single Jet Water Meters with Pulse Output

Single Jet Water Meters with Pulse Output

Dynamic Balancing / Differential Pressure Balancing Valve

Dynamic Balancing / Differential Pressure Balancing Valve

Pressure Gauges

Pressure Gauges

ESTRON EN 13190 thermometer

Thermometers

Assembly / Disassembly Parts

Assembly / Disassembly Parts

Brass Water Meter Coupling

Brass Water Meter Coupling

ATLAS M-Bus Converter

M-Bus Converters

ATLAS EH-20

Electromechanical Water Meters

ATLAS termostatik radyatör vanası – oda sıcaklığı kontrolü ve radyatör tesisatı uygulaması

Thermostatic Radiator Valves

Size Nasıl Yardımcı Olabiliriz?